HAISHAN INDUSTRY · GLOBAL PROJECT SOLUTIONS

Aluminium conductor steel reinforced (ACSR)

Back to cable catalogue
OVERHEAD · Cable family

Construction & selection

Aluminium conductor steel reinforced (ACSR) family. Outer aluminium strands surround a steel reinforcing core. Aluminium/steel construction ratios, mechanical strength and dimensions are configuration-specific.

For technical data and a quotation, use Contact in the main navigation and include this cable family in your enquiry.

Representative illustration: Aluminium conductor steel reinforced (ACSR)
Representative illustration of one configuration. Actual construction, colour and dimensions depend on the selected specification.

Construction

Illustrated variant: ACSR aluminium over steel reinforcement

Representative construction of ACSR aluminium over steel reinforcement, with numbered components 1 to 2, explained below.
Representative construction of the selected variant; not to scale. Strand counts, colours and dimensions are illustrative.
  1. Steel reinforcing core

    The central steel core reinforces the aluminium conductor strands laid around it.

  2. Aluminium conductor strands

    Aluminium conductor strands form the conducting layers around the central steel reinforcing core.

Construction source: supplier overhead conductor reference catalogue, page 15.

Family reference

Illustrated conductorAluminium with steel reinforcement
Illustrated configurationACSR aluminium strands with steel central reinforcement
Construction layerscentral steel reinforcement; concentric outer aluminium strands
Selection requirementConfirm size, rated voltage, installation conditions and applicable standards before ordering

Engineering data

Manufacturer catalogue reference: PDF page 15 (printed page 11).

BS 215 (Part 2)-1970 (catalogue statement)

Aluminium conductor steel reinforced (ACSR) — catalogue reference values
Code wordNominal aluminium area (mm²)Aluminium stranding (No./mm)Steel stranding (No./mm)Total sectional area (mm²)Approx. overall diameter (mm)Maximum DC resistance at 20°C (Ω/km)Approx. conductor weight (kg/km)
GOPHER256/2.361/2.3630.627.081.093106
WEASEL306/2.591/2.5936.887.770.9077128
FERRET406/3.001/3.0049.489.000.6766172
RABBIT506/3.351/3.3561.710.050.5426214
HORSE7012/2.797/2.79116.213.950.3936538
DOG1006/4.727/1.57118.514.150.2733394
WOLF15030/2.597/2.59194.918.130.1828726
DINGO15018/3.351/3.35167.516.750.1815506
LYNX17530/2.797/2.79226.219.530.1576842
CARACAL17518/3.611/3.61194.518.030.1563587
PANTHER20030/3.007/3.00261.521.000.1363974
JAGUAR20018/3.861/3.86222.319.300.1367671
ZEBRA40054/3.187/3.18484.528.620.06741621
  • The source breaking-load unit is incorrectly printed as “Metre±10%”. Breaking-load values are withheld pending a corrected manufacturer unit; no conversion to kN has been assumed.
  • Values are transcribed from the supplied manufacturer catalogue, not independently certified test results. Final construction, applicable standard edition and project suitability require technical review.

Project-specific confirmation

Confirm the required conductor material, core arrangement, voltage designation, installation conditions, size and applicable standards with your enquiry. Reference tables on this page give data for the stated construction; confirm the selected current datasheet before ordering.

Illustrations are not engineering drawings or factory photographs. Final specifications and approved drawings will be confirmed with our official quotation. No certification or current manufacturer availability is implied by this family overview.