HAISHAN INDUSTRY · GLOBAL PROJECT SOLUTIONS

All aluminium alloy conductors (AAAC)

Back to cable catalogue
OVERHEAD · Cable family

Construction & selection

All-aluminium alloy conductor (AAAC) family with bare stranded aluminium-alloy construction and no steel core. The illustration is representative; alloy and mechanical requirements must be confirmed in the selected datasheet.

For technical data and a quotation, use Contact in the main navigation and include this cable family in your enquiry.

Representative illustration: All aluminium alloy conductors (AAAC)
Representative illustration of one configuration. Actual construction, colour and dimensions depend on the selected specification.

Construction

Illustrated variant: AAAC bare aluminium alloy

Representative construction of AAAC bare aluminium alloy, with numbered components 1 to 2, explained below.
Representative construction of the selected variant; not to scale. Strand counts, colours and dimensions are illustrative.
  1. Aluminium-alloy strands

    Aluminium-alloy strands make up the bare current-carrying conductor.

  2. Bare stranded conductor assembly

    The strands are laid together as a bare conductor, without insulation or an outer sheath.

Construction source: supplier overhead conductor reference catalogue, page 23.

Family reference

Illustrated conductorAluminium alloy
Illustrated configurationAAAC bare stranded aluminium alloy
Construction layersaluminium alloy strands only
Selection requirementConfirm size, rated voltage, installation conditions and applicable standards before ordering

Engineering data

Manufacturer catalogue reference: PDF page 23 (printed page 19).

BS EN 50182-2001 (catalogue statement)

All aluminium alloy conductor (AAAC) — catalogue reference values
Code wordNominal area (mm²)Wire number / diameter (No./mm)Approx. overall diameter (mm)Maximum resistance at 20°C (Ω/km)Approx. conductor weight (kg/km)Breaking load (kN)
BOX18.87/1.855.551.74851.45.55
ACACIA23.87/2.086.241.382864.97.02
ALMOND30.17/2.347.021.092682.28.88
CEDAR35.57/2.547.620.927396.810.46
DEODAR42.27/2.778.310.7797Not specified12.44
FIR47.87/2.958.850.6875130.614.11
HAZEL59.97/3.309.900.5494163.417.66
PINE71.67/3.6110.800.4591195.621.14
HOLLY84.17/3.9111.700.3913229.524.79
WILLOW89.77/4.0412.100.3665245.026.47
OAK118.97/4.6514.000.2767324.535.07
MULBERRY150.919/3.1815.900.2192414.344.52
ASH180.719/3.4817.400.183496.153.31
ELM211.019/3.7618.800.1568579.262.24
POPLAR239.437/2.8720.100.1387659.470.61
SYCAMORE303.237/3.2322.600.1095835.289.4
UPAS362.137/3.5324.700.0917977.5106.82
YEW479.037/4.0628.400.06931319.6141.31
TOTARANot specified37/4.1429.000.06661372.1146.93
RUBUS586.961/3.5031.500.05671622.0173.13
SORBUS659.461/3.7133.400.05051822.5194.53
ARAUCARIA821.161/4.1437.300.04062269.4242.24
REDWOOD996.261/4.5641.000.033452753.2293.88
  • The source TOTARA nominal area and DEODAR weight are unresolved; affected cells are withheld without altering other row data.
  • Values are transcribed from the supplied manufacturer catalogue, not independently certified test results. Final construction, applicable standard edition and project suitability require technical review.

Project-specific confirmation

Confirm the required conductor material, core arrangement, voltage designation, installation conditions, size and applicable standards with your enquiry. Reference tables on this page give data for the stated construction; confirm the selected current datasheet before ordering.

Illustrations are not engineering drawings or factory photographs. Final specifications and approved drawings will be confirmed with our official quotation. No certification or current manufacturer availability is implied by this family overview.