INDUSTRIAL VALVES & FLOW CONTROL TECHNICAL DATA

MODEL SG-063-2

Top-Entry Eccentric Hemispherical Valve

Product enquiry
SG-063-2 valve product
Product photograph
01

CONSTRUCTION

Materials / Main Components

No.Part NameMaterial
1BodyWCB / ZG1Cr18Ni9Ti / ZG0Cr18Ni12Mo2Ti / ZG15Cr1Mo1V
2Rear bonnetQ235A / 1Cr18Ni9Ti / 0Cr18Ni12Mo2Ti / 25Cr2Mo1V
3Shaft sleeveSF-1 / FB090 / FB316 / FB090
4Lower stem2Cr13 / 1Cr18Ni9Ti / 0Cr18Ni12Mo2Ti / 1Cr18Ni9Ti
5Ball bodyWCB / ZG1Cr18Ni9Ti / ZG0Cr18Ni12Mo2Ti / ZG15Cr1Mo1V
6PlatenQ235A / 1Cr18Ni9Ti / 0Cr18Ni12Mo2Ti / 25Cr2Mo1V
7Valve seatQ235A+PTFE / 1Cr18Ni9Ti/PTFE / 0Cr18Ni12Mo2Ti/PTFE / 25Cr2Mo1V/PTFE
8Ball1Cr18Ni9Ti with special treatment / 1Cr18Ni9Ti with special treatment / 0Cr18Ni12Mo2Ti with special treatment / 1Cr18Ni9Ti with special treatment
9Shaft sleeveSF-1 / FB090 / FB316 / FB090
10Upper stem2Cr13 / 1Cr18Ni9Ti / 0Cr18Ni12Mo2Ti / 1Cr18Ni9Ti
11Packing discWCB / ZG1Cr18Ni9Ti / ZG0Cr18Ni12Mo2Ti / ZG15Cr1Mo1V
12BonnetWCB / ZG1Cr18Ni9Ti / ZG0Cr18Ni12Mo2Ti / ZG15Cr1Mo1V
13Bolt35 / 0Cr18Ni9 / 0Cr18Ni9 / 15Cr1Mo1V
13Nut45 / 0Cr18Ni9 / 0Cr18Ni9 / 20CrMo
14PackingFlexible graphite / Flexible graphite / Flexible graphite / Flexible graphite
15BonnetWCB / ZG1Cr18Ni9Ti / ZG0Cr18Ni12Mo2Ti / ZG15Cr1Mo1V
16SupportWCB / WCB / WCB / WCB
17Electric actuatorKTQ
02

RATING & STANDARDS

Main Technical Parameters

Nominal pressure
PN10/PN16/PN25/PN40/PN64
Flange connection standard
GB/T17241.6; GB/T9113-2010
Test standard
GB/T13927-2008
Applicable media
Water, oil, gas, etc.
Leakage rate
<0.1 × DN mm³/s (GB/T13927-2005)
Applicable temperature
Soft seal: -40°C to 350°C; hard seal: -50°C to 600°C
Drive type
Worm gear, electric, pneumatic, hydraulic
Ordering requirements
Specify operating temperature and media.
03

SECTIONAL ILLUSTRATIONS

Sectional Illustrations

SG-063-2 sectional illustration
Drawings shown are for reference. Project-specific technical drawings will be provided with our formal quotation.
04

OPERATING LIMITS

Pressure Conditions

Listed operating and test pressures depend on the selected configuration. Confirm the applicable values and service conditions against the approved product submittal before selection.

Pressure familyPressure / class designationShell test pressure (MPa)Air tightness test pressure (MPa)High-pressure sealing test pressure (MPa)
PN1.01.50.61.1
PN1.62.40.61.76
PN2.53.80.62.75
PN4.06.00.64.4
PN6.49.60.67.1
Class150Lb3.00.62.2
Class300Lb7.50.65.5
Class600Lb15.00.611.0
Class900Lb22.50.616.5
05

DIMENSIONAL DATA

Dimensions

Scroll horizontally to view all dimensions.

1.0 MPa — DYQ340F/DYQ340H/DYQ340Y/DYQ640F/DYQ640H/DYQ640Y/DYQ940F/DYQ940H/DYQ940Y-10(C, L, P, R)
DNLDKdbfz-d0HwHd
50180160125991824-Φ18295350
802002001601322028-Φ18310365
1002292201801562228-Φ18330380
1252542502101842228-Φ18345405
1502672852402112428-Φ22370440
2002923402952662428-Φ22405470
25033039535031926212-Φ22480540
30039044540037026212-Φ22520580
35043050546042926216-Φ22570630
40053056551548026216-Φ26630710
45058061556553028220-Φ26690770
50066067062058228220-Φ26740820
60084078072568234220-Φ30840940
70090089584079434524-Φ309601040
8001000101595090136524-Φ3310801180
900110011151050100138528-Φ3311901280
1000120012301160111238528-Φ3613101420
1100125013401270122242528-Φ3613901480
1200130014551380132844532-Φ3914201530
1400150016751590153048536-Φ4215401650
1600180019151820175052540-Φ4816601750
1800200021152020195056544-Φ4817901860
2000220023252230215060548-Φ4819201990
1.6 MPa — DYQ340F/DYQ340H/DYQ340Y/DYQ640F/DYQ640H/DYQ640Y/DYQ940F/DYQ940H/DYQ940Y-16/25(C, L, P, R)
DNLDKdbfz-d0HwHd
5018016012599182-295350
80200200160132202-310365
100229220180156222-330380
125254250210184222-345405
150267285240211242-370440
200292340295266242-405470
250330405350319262-480540
300390460400370282-520580
350430520460429302-570630
400530580515480322-630710
450580640565530402-690770
500660715620582442-740820
600840840725682542-840940
700900910840794505-9601040
80010001025950901425-10801180
9001100112510501001445-11901280
10001200125511601112465-13101420
11001250137012801222485-13901480
12001300148513801328525-14201530
14001500168515901530585-15401650
16001800193018201750645-16601750
18002000213020201950685-17901860
20002200234522302150705-19201990

Flange thickness and raised-face details for this pressure class require confirmation against the approved drawing.

2.5 MPa — DYQ340F/DYQ340H/DYQ340Y/DYQ640F/DYQ640H/DYQ640Y/DYQ940F/DYQ940H/DYQ940Y-16/25(C, L, P, R)
DNLDKdz-d0HwHd
50180160125994-Φ18295350
802002001601328-Φ18310365
1002292351901568-Φ22330380
1252542702201848-Φ26345405
1502673002502118-Φ26370440
20029236031027412-Φ26405470
25033042537033012-Φ30480540
30039048543038916Φ30520580
35043055549044816-Φ33570630
40053062055050316-Φ36630710
45058067060054820-Φ36690770
50066073066060920-Φ36740820
60084084577072020-Φ39840940
70090096087582024-Φ429601040
8001000108599092824-Φ4810801180
900110011851090102828-Φ4811901280
1000120013201210114028-Φ5513101420
1100125014251315124528-Φ5513901480
1200130015301420135032-Φ5514201530
1400150017551640156036-Φ6015401650
1600180019751860178040-Φ6016601750
1800200021952070198544-Φ6817901860
2000220024252300221048-Φ6819201990

Verify the selected configuration and service duty against the approved product submittal.

SG-063-2 sectional illustration