Three-core copper XLPE cable example with copper-tape screens, common PVC bedding, steel-wire armour and PVC sheath. The family designation follows the reference catalogue; exact U0/U(Um), insulation dimensions and project compliance must be confirmed in the current selected datasheet.

For technical data and a quotation, use Contact in the main navigation and include this cable family in your enquiry.

Representative illustration: 12.7/22 kV XLPE Power Cables
Representative illustration of one configuration. Actual construction, colour and dimensions depend on the selected specification.

Construction

Illustrated variant: Three-core CU/XLPE/CTS/PVC/SWA/PVC, selected PVC outer-sheath branch

Representative construction of Three-core CU/XLPE/CTS/PVC/SWA/PVC, selected PVC outer-sheath branch, with numbered components 1 to 9, explained below.
Representative construction of the selected variant; not to scale. Strand counts, colours and dimensions are illustrative.
  1. Compacted stranded copper conductors

    Copper strands are compacted together to form each current-carrying conductor.

  2. Semiconducting conductor screens

    A semiconducting layer around each conductor forms its inner electrical screen.

  3. XLPE insulation

    Cross-linked polyethylene forms the main electrical insulation around each conductor.

  4. Semiconducting insulation screens

    A semiconducting layer around each XLPE-insulated core forms its outer insulation screen.

  5. Copper tape screens

    Copper tape forms the metallic screen around each individual insulated core.

  6. Core assembly and fillers

    The insulated cores are assembled together, with fillers occupying the spaces between them.

  7. PVC bedding

    PVC forms a bedding layer between the insulated core assembly and the armour.

  8. Steel wire armour

    Steel wires form the mechanical armour around the cable.

  9. PVC outer sheath

    PVC forms the external protective covering around the cable assembly.

The illustrated variant uses a PVC outer sheath. The source also lists a PE alternative; that alternative is not shown.

Construction source: supplier MV reference catalogue, page 28.

Family reference

Illustrated conductorCopper
Illustrated configurationThree-core CU/XLPE/CTS/PVC/SWA/PVC
Construction layersthree compacted stranded copper cores; each: conductor semiconductor / XLPE / insulation semiconductor / copper tape screen; fillers and common PVC bedding; steel wire armour; PVC outer sheath
Selection requirementConfirm size, rated voltage, installation conditions and applicable standards before ordering

Technical specifications

12.7/22 kV three-core copper XLPE cable · Highest system voltage: 24 kV · CU/XLPE/CTS/PVC/SWA/PVC(PE)

Supplier catalogue reference, not a quotation, certificate or project-compliance approval. Overall dimensions, weights and drum dimensions are approximate guidance. Confirm current construction and packing with the supplier.

Circular compacted copper; numeric class not stated on selected source page.

Supplier medium-voltage catalogue, PDF page 28 (printed 24)
Nominal conductor area (mm²)Maximum conductor resistance at 20°C (Ω/km)XLPE insulation thickness (mm)Copper tape thickness (mm)Extruded bedding thickness (mm)Armour wire diameter (mm)Outer sheath thickness (mm)Approximate overall diameter (mm)Approximate cable weight (kg/km)Standard packing length (m ±10%)Drum sizeApproximate gross weight (kg)
350.5245.50.0751.52.52.757.44710500D-192680
500.3875.50.0751.62.52.860.25130500D-223040
700.2685.50.0751.62.52.964.25740500D-233370
950.1935.50.0751.72.53.273.28870500D-234940
1200.1535.50.0751.73.153.37810730250D-213100
1500.1245.50.0751.83.153.481.412000250D-233500
1850.09915.50.0751.93.153.685.513460200D-223160
2400.07545.50.07523.153.791.315780200D-233660
3000.06015.50.07523.153.99618110200D-244220
4000.0475.50.0752.23.154.110321500200D-244900

Source notes and standards

  • All conductors circular compacted.
  • Equivalent voltage designation as per IEC 60502-2: 12/20 kV (catalogue statement).
  • Catalogue states: Cables conform to IEC 60502-2. This is a supplier statement, not independent certification or project approval; edition not stated.

Project-specific confirmation

Confirm the required conductor material, core arrangement, voltage designation, installation conditions, size and applicable standards with your enquiry. Reference tables on this page give data for the stated construction; confirm the selected current datasheet before ordering.