Construction & selection
Single-core copper XLPE cable example with a copper-wire-and-tape screen, LSZH inner and outer sheaths, and aluminium-wire armour. The family designation follows the reference catalogue; exact U0/U(Um), insulation dimensions and project compliance must be confirmed in the current selected datasheet.
For technical data and a quotation, use Contact in the main navigation and include this cable family in your enquiry.

Construction
Illustrated variant: CU/XLPE/CWS/LSZH/AWA/LSZH
- Compacted stranded copper conductor
Copper strands are compacted together to form the current-carrying conductor.
- Semiconducting conductor screen
A semiconducting layer around the conductor forms the inner electrical screen.
- XLPE insulation
Cross-linked polyethylene forms the main electrical insulation around the conductor.
- Semiconducting insulation screen
A semiconducting layer around the XLPE insulation forms the outer insulation screen.
- Copper wire and tape screen
Copper wires and copper tape together form the metallic screen around the insulated core.
- LSZH inner sheath
The low-smoke zero-halogen inner sheath separates the screened core from the armour.
- Aluminium wire armour
Aluminium wires form the mechanical armour around the cable.
- LSZH outer sheath
The low-smoke zero-halogen material forms the external protective sheath.
Construction source: supplier MV reference catalogue, page 33.
Family reference
| Illustrated conductor | Copper |
|---|---|
| Illustrated configuration | Single-core CU/XLPE/CWS/LSZH/AWA/LSZH |
| Construction layers | compacted stranded copper; semiconducting conductor screen; XLPE insulation; semiconducting insulation screen; copper wire and tape screen; LSZH inner sheath; aluminium wire armour; LSZH outer sheath |
| Selection requirement | Confirm size, rated voltage, installation conditions and applicable standards before ordering |
Technical specifications
26/35 kV single-core copper XLPE cable · Highest system voltage: 42 kV · CU/XLPE/CWS/LSZH/AWA/LSZH
Supplier catalogue reference, not a quotation, certificate or project-compliance approval. Overall dimensions, weights and drum dimensions are approximate guidance. Confirm current construction and packing with the supplier.
Circular compacted copper; numeric class not stated on selected source page.
| Nominal conductor area (mm²) | Maximum conductor resistance at 20°C (Ω/km) | XLPE insulation thickness (mm) | Copper wire and tape area (unit unresolved) | Inner sheath thickness (mm) | Armour wire diameter (mm) | Outer sheath thickness (mm) | Approximate overall diameter (mm) | Approximate cable weight (kg/km) | Standard packing length (m ±10%) | Drum size | Approximate gross weight (kg) |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 50 | 0.387 | 10.5 | Not published* | 1.3 | 2.5 | 2.4 | 47.5 | 2922 | 500 | D-18 | 1470 |
| 70 | 0.268 | 10.5 | Not published* | 1.3 | 2.5 | 2.5 | Not published* | 3269 | 500 | D-18 | Not published* |
| 95 | 0.193 | 10.5 | Not published* | 1.3 | 2.5 | 2.5 | 51.2 | 3616 | 500 | D-18 | 1800 |
| 120 | 0.153 | 10.5 | Not published* | 1.4 | 2.5 | 2.6 | 53.0 | 3989 | 500 | D-18 | Not published* |
| 150 | 0.124 | 10.5 | Not published* | 1.4 | 2.5 | 2.6 | 54.6 | 4347 | 500 | D-19 | 2310 |
| 185 | 0.0991 | 10.5 | Not published* | 1.4 | 2.5 | 2.7 | 56.4 | 4821 | 500 | D-19 | 2520 |
| 240 | 0.0754 | 10.5 | Not published* | 1.5 | 2.5 | 2.8 | 59.0 | 5547 | 500 | D-19 | 2860 |
| 300 | 0.0601 | 10.5 | Not published* | 1.5 | 2.5 | 2.8 | 61.2 | 6243 | 500 | D-21 | 3380 |
| 400 | 0.047 | 10.5 | Not published* | 1.6 | 2.5 | 3.0 | 64.6 | 7303 | 500 | D-22 | 3890 |
| 500 | 0.0366 | 10.5 | Not published* | 1.6 | 2.5 | 3.1 | 68.1 | 8554 | 500 | D-22 | 4580 |
| 630 | 0.0283 | 10.5 | Not published* | 1.7 | 2.5 | 3.2 | 71.9 | 10117 | 500 | D-21-M | 5490 |
Source notes and standards
- All conductors circular compacted.
- The source line “Equivalent voltage designation as per IEC 60502-2” gives no equivalent value.
- Catalogue states: Cables conform to IEC 60502-2. This is a supplier statement, not independent certification or project approval; edition not stated.
- The cited IEC 60502-2 statement for this 26/35 kV family requires supplier clarification; no compliance claim is adopted here.
Selected data qualifications
- 50 mm² / Copper wire and tape area: Value withheld pending source confirmation.
- 70 mm² / Copper wire and tape area: Value withheld pending source confirmation.
- 95 mm² / Copper wire and tape area: Value withheld pending source confirmation.
- 120 mm² / Copper wire and tape area: Value withheld pending source confirmation.
- 150 mm² / Copper wire and tape area: Value withheld pending source confirmation.
- 185 mm² / Copper wire and tape area: Value withheld pending source confirmation.
- 240 mm² / Copper wire and tape area: Value withheld pending source confirmation.
- 300 mm² / Copper wire and tape area: Value withheld pending source confirmation.
- 400 mm² / Copper wire and tape area: Value withheld pending source confirmation.
- 500 mm² / Copper wire and tape area: Value withheld pending source confirmation.
- 630 mm² / Copper wire and tape area: Value withheld pending source confirmation.
- 70 mm² / Approximate overall diameter: Value withheld pending source confirmation.
- 70 mm² / Approximate gross weight: Value withheld pending source confirmation.
- 120 mm² / Approximate gross weight: Value withheld pending source confirmation.
Project-specific confirmation
Confirm the required conductor material, core arrangement, voltage designation, installation conditions, size and applicable standards with your enquiry. Reference tables on this page give data for the stated construction; confirm the selected current datasheet before ordering.
Illustrations are not engineering drawings or factory photographs. Final specifications and approved drawings will be confirmed with our official quotation. No certification or current manufacturer availability is implied by this family overview.