Construction & selection
All-aluminium alloy conductor (AAAC) family with bare stranded aluminium-alloy construction and no steel core. The illustration is representative; alloy and mechanical requirements must be confirmed in the selected datasheet.
For technical data and a quotation, use Contact in the main navigation and include this cable family in your enquiry.

Construction
Illustrated variant: AAAC bare aluminium alloy
- Aluminium-alloy strands
Aluminium-alloy strands make up the bare current-carrying conductor.
- Bare stranded conductor assembly
The strands are laid together as a bare conductor, without insulation or an outer sheath.
Construction source: supplier overhead conductor reference catalogue, page 23.
Family reference
| Illustrated conductor | Aluminium alloy |
|---|---|
| Illustrated configuration | AAAC bare stranded aluminium alloy |
| Construction layers | aluminium alloy strands only |
| Selection requirement | Confirm size, rated voltage, installation conditions and applicable standards before ordering |
Engineering data
Manufacturer catalogue reference: PDF page 23 (printed page 19).
BS EN 50182-2001 (catalogue statement)
| Code word | Nominal area (mm²) | Wire number / diameter (No./mm) | Approx. overall diameter (mm) | Maximum resistance at 20°C (Ω/km) | Approx. conductor weight (kg/km) | Breaking load (kN) |
|---|---|---|---|---|---|---|
| BOX | 18.8 | 7/1.85 | 5.55 | 1.748 | 51.4 | 5.55 |
| ACACIA | 23.8 | 7/2.08 | 6.24 | 1.3828 | 64.9 | 7.02 |
| ALMOND | 30.1 | 7/2.34 | 7.02 | 1.0926 | 82.2 | 8.88 |
| CEDAR | 35.5 | 7/2.54 | 7.62 | 0.9273 | 96.8 | 10.46 |
| DEODAR | 42.2 | 7/2.77 | 8.31 | 0.7797 | Not specified | 12.44 |
| FIR | 47.8 | 7/2.95 | 8.85 | 0.6875 | 130.6 | 14.11 |
| HAZEL | 59.9 | 7/3.30 | 9.90 | 0.5494 | 163.4 | 17.66 |
| PINE | 71.6 | 7/3.61 | 10.80 | 0.4591 | 195.6 | 21.14 |
| HOLLY | 84.1 | 7/3.91 | 11.70 | 0.3913 | 229.5 | 24.79 |
| WILLOW | 89.7 | 7/4.04 | 12.10 | 0.3665 | 245.0 | 26.47 |
| OAK | 118.9 | 7/4.65 | 14.00 | 0.2767 | 324.5 | 35.07 |
| MULBERRY | 150.9 | 19/3.18 | 15.90 | 0.2192 | 414.3 | 44.52 |
| ASH | 180.7 | 19/3.48 | 17.40 | 0.183 | 496.1 | 53.31 |
| ELM | 211.0 | 19/3.76 | 18.80 | 0.1568 | 579.2 | 62.24 |
| POPLAR | 239.4 | 37/2.87 | 20.10 | 0.1387 | 659.4 | 70.61 |
| SYCAMORE | 303.2 | 37/3.23 | 22.60 | 0.1095 | 835.2 | 89.4 |
| UPAS | 362.1 | 37/3.53 | 24.70 | 0.0917 | 977.5 | 106.82 |
| YEW | 479.0 | 37/4.06 | 28.40 | 0.0693 | 1319.6 | 141.31 |
| TOTARA | Not specified | 37/4.14 | 29.00 | 0.0666 | 1372.1 | 146.93 |
| RUBUS | 586.9 | 61/3.50 | 31.50 | 0.0567 | 1622.0 | 173.13 |
| SORBUS | 659.4 | 61/3.71 | 33.40 | 0.0505 | 1822.5 | 194.53 |
| ARAUCARIA | 821.1 | 61/4.14 | 37.30 | 0.0406 | 2269.4 | 242.24 |
| REDWOOD | 996.2 | 61/4.56 | 41.00 | 0.03345 | 2753.2 | 293.88 |
- The source TOTARA nominal area and DEODAR weight are unresolved; affected cells are withheld without altering other row data.
- Values are transcribed from the supplied manufacturer catalogue, not independently certified test results. Final construction, applicable standard edition and project suitability require technical review.
Project-specific confirmation
Confirm the required conductor material, core arrangement, voltage designation, installation conditions, size and applicable standards with your enquiry. Reference tables on this page give data for the stated construction; confirm the selected current datasheet before ordering.
Illustrations are not engineering drawings or factory photographs. Final specifications and approved drawings will be confirmed with our official quotation. No certification or current manufacturer availability is implied by this family overview.